Bio-Med Inc Bio-Med Inc
Home About Us Products Sales Query Service Support Contact Us
Product Categories
wIRA Therapy
ZRT Matrix Therapy
Physiotherapy Equipments
Occupational Therapy Equipments
Rehabilitation Aids / Products
Sports Medicine
Slimming & Beauty Products
Measurement and Evaluation Equipments
Physiotherapy Equipments
Laser Therapy Equipments
LASER THERAPY (BMI-1123)
LASER THERAPY (BMI-1123)



• Treatment clock 1 s. - 99 min

• Power supply 230 V / 50 Hz / 50 VA

• Dimensions 335 x 270 x 125 mm

• Weight 2.5 kg

Available laser probes

Type of probe     Parameters        Modes of work

S-1N - point IR    905nm / 50mW    mpulse - high power impulse (50W)

S-2N - point R   660nm / 40mW   constant and modulated with average power regulation

S-3N - point IR   808nm / 400mW   constant and modulated with average power regulation

Technical data of probes

Type of probe S-1N, S-2N, S-3N

Wavelength 905 nm, 660 nm, 808 nm

Pulse power 50 W:40 mW, 400 mW

Frequency 5-5000Hz, 5-9999Hz, 5-9999Hz

Mean power (0,1-50)mW, (1-40)mW, (1-400)mW

Pulse energy 10 µJ, ---, ----

Width of pulse 200ns, ---- , ----

Accessories

Optional laser probes chosen separately according to user"s needs. Protective eyewear for all related wavelengths.

Go to top of page
LASERMED-2200 - Double Output (BMI-1005)
LASERMED-2200 - Double Output (BMI-1005)



• Wavelength - 905 nm

• Display :- Colour Graphic 320x240 with Touch & Scroll

• Output channel :- 2 indipendent

• Frequency :- From 200 to 10.000 Hz

• Stored Protocols :- 85

• Storable Protocols on internal memory :-200

• Storable Protocols on Smart Card :- 200

• with 2 probes (1 diode 100mW and 8 diodes 800mW
Go to top of page
CRYSTAL YAG DESK (BMI-1007)
CRYSTAL YAG DESK (BMI-1007)



• Mac 1271 - ViKare 4W: effective peak power 4W

• Mac 1272 - ViKare 8W: effective peak power 8W

• TECHNICAL CHARACTERISTICS

• Wave length: 940 nm

• Programmes in memory: 85

• Frequency: up to 10.000 Hz

• Spacer for defocusing laser spot

• 6"colour touch screen display

• Patient forms integrated in memory
Go to top of page
DIGITAL LASER THERAPY WITH SCANNER (BMI-1003)
DIGITAL LASER THERAPY WITH SCANNER (BMI-1003)



Specifications

• STL-101.....TeraMed

• Laser source : Diode (GaAIAs)

• Main Power : 220/60Hz

• Laser radiation

• Output power: 50mW

• Wavelength : 650 nm (GaAIAs)

• Radiation Time : 1-99 min

Go to top of page
LASER THERAPY WITH SCANNER (BMI-1004)
LASER THERAPY WITH SCANNER (BMI-1004)



SPECIFICATIONS:



» Two Speed Horizontal/Vertical Scanning

» Two Integrated sources for laser emission :

1. One at Soild State (Visible)

2. One at IR (6 Diodes).

» Connector maniple for external IR Laser.

• High Power Automatic

• Scanning Laser

• Laser therapy with scanning of pain areas



Available Models:

• PR 999 150 mW

• PR 999 500 mW

• PR 999 2W